1. 1RWH ,Q WKH SDVW PRVW ODUJH ORZ VSHHG PDLQ SURSXOVLRQ GLHVHO HQJLQHV ZHUH YDOYH OHVV XWLOL]LQJ HLWKHU FURVV ÁRZ RU ORRS VFDYHQJLQJ WR UHPRYH H[KDXVW JDVHV IURP WKH F\OLQGHU YLD H[KDXVW SRUWV LQ WKH F\OLQGHU OLQHU 7RGD\ ODUJH ORZ VSHHG PDLQ SURSXOVLRQ GLHVHO HQJLQHV SULPDULO\ XWLOL]H XQLÁRZ VFDYHQJLQJ in which each cylinder features one centrally located exhaust valve.
A. mechanical pushrods.
Incorrect Answer: Medium and high speed diesels engines equipped with the conventional over- head valve arrangement utilize mechanical pushrods. The pushrod, along with the camshaft lobe, cam follower, and rocker arm are the means by which valve is opened. The valve is closed by spring force.
B. compressed air pressure &RUUHFW; $QVZHU ([KDXVW YDOYHV RQ PRGHUQ ODUJH VORZ VSHHG XQLÁRZ VFDYHQJHG PDLQ SUR- SXOVLRQ GLHVHO HQJLQHV DUH ÀWWHG ZLWK H[KDXVW YDOYH DFWXDWRUV XWLOL]LQJ ÁXLG SRZHU IRU YDOYH operation. The valves are opened under hydraulic pressure and are closed with compressed air pressure. The air actuator is sometimes called an air spring, since it performs the same function as conventional valve springs (valve closure) using compressed air.
& K\GUDXOLF SUHVVXUH D. exhaust pressure
,QFRUUHFW $QVZHU $V H[SODLQHG LQ FKRLFH ´%µ DERYH K\GUDXOLF SUHVVXUH LV WKH H[KDXVW YDOYH opening force, not the closing force.
Incorrect Answer: Exhaust gas is not a suitable media for exhaust valve operation. Exhaust gas is not high enough in pressure to close the exhaust valve.
2. Note: Controllers that feature proportional action exhibit a unique behavior. The set point value, as the name implies, is the setting of the controlled process that the controller is designed to maintain. Ideally, the set point value and the actual measured value are identical. As with all process control action types, with load or demand changes the measured value will differ from the set point value. This difference is called deviation (or error), which causes a corrective response. As the controller reacts to the deviation, the controlled variable will stabilize at a value proportional to the load or demand, and it will be different from the set point value. This difference is called offset. The new point at which the controlled variable stabilizes is called the control point.
A. offset B.
deviation ' ORDG SRLQW
Incorrect Answer: Offset is the difference between the set point value and the control point value. Incorrect Answer: Deviation is the difference between the set point value and the measured value.
C. control point Correct Answer: The value at which the controlled variable stabilizes is called the control point. It will vary with the load or demand.
,QFRUUHFW $QVZHU /RDG SRLQW LV D ÀFWLWLRXV WHUP 7KH SRLQW DW ZKLFK WKH FRQWUROOHG YDULDEOH ZLOO VWDELOL]H IRU a given load is called the control point, not the load point.
$ õ +3 ,QFRUUHFW $QVZHU 7KH õ +3 +3 PRWRU LV WRR VPDOO WR RSHUDWH WKH SXPS % ô +3
&RUUHFW; $QVZHU 7KH ô +3 +3 PRWRU LV WKH VPDOOHVW KRUVHSRZHU PRWRU DYDLODEOH WR HIIHFWLYHO\ RSHUDWH WKH
pump. See solution below. Solution: The potential energy gained by the liquid is equal to the weight of the liquid pumped, multiplied by the height it is to be discharged, multiplied by the pump capacity.
Expressed mathematically: (8.58 lb/min) (100 gal/min) (15 ft) = 12,870 foot-pounds 8VLQJ WKH FRQYHUVLRQ IDFWRU RI WKH SXPS ZRXOG EH
IRRW SRXQGV SHU PLQ ¸
& ö +3 ' +3
4.
7KH PHFKDQLFDO HIÀFLHQF\ RI WKH SXPS LV ¸ PHFKDQLFDO HIÀFLHQF\ ,QFRUUHFW $QVZHU 7KH ö +3 operate the pump.
IRRW SRXQGV SHU PLQXWH KRUVHSRZHU 7KH WKHRUHWLFDO +3 UHTXLUHG WR RSHUDWH IRRW SRXQGV SHU PLQ SHU +3 +3
VR DFWXDO +3 UHTXLUHG WR RSHUDWH WKH SXPS ZRXOG EH +3
+3 0LQLPXP +3 RI PRWRU UHTXLUHG WR HIIHFWLYHO\ RSHUDWH WKH SXPS +3 PRWRU FRXOG RSHUDWH WKH SXPS EXW LV QRW WKH VPDOOHVW +3 PRWRU DYDLODEOH WR
,QFRUUHFW $QVZHU 7KH +3 PRWRU FRXOG RSHUDWH WKH SXPS EXW LV QRW WKH VPDOOHVW +3 PRWRU DYDLODEOH WR RSHUDWH WKH pump.
A. air ejector inter-condenser &RUUHFW; $QVZHU &RQGHQVDWH; GLVFKDUJHG E\ WKH PDLQ FRQGHQVDWH SXPS ÀUVW SDVVHV WKURXJK WKH tubes of the air ejector inter-condenser. The condensate passing through the inter-condenser tubes condenses the steam/gas mixture discharged to the inter-condenser shell E\ WKH ÀUVW VWDJH air ejector unit. The resultant condensate drops to the bottom of the inter-condenser shell, and drains back to the main condenser via a U-shaped loop seal.
B. main condenser hotwell C. air ejector after-condenser
Incorrect Answer: The main condensate pump takes suction from the main condenser hot-well.
Incorrect Answer: Upon exiting the air ejector inter-condenser tubes, condensate from the main FRQGHQVDWH SXPS WKHQ ÁRZV WKURXJK WKH WXEHV RI WKH DLU HMHFWRU DIWHU FRQGHQVHU 7KH FRQGHQVDWH passing through the after-condenser tubes condenses the steam/gas mixture discharged to the after-condenser shell by the second stage air ejector unit. The resultant condensate drops to the bottom of the after-condenser shell, and drains back to the atmospheric drain tank.
D. DC heater vent condenser
Incorrect Answer: Condensate discharged by the main condensate pump must pass through the air ejector condenser unit and gland exhaust condenser before entering the DC heater vent condenser.